Number:

Turbo Series EVI Inverter Swimming Pool Heat Pump


EVI technology conquers all climates

Product Categories: Swimming Pool Heat pump
· R32 refrigerant· Inverter technology – variable operating speed · Operating ambient temperature -25°C and 43°C · Wi-Fi included as standard · Heating and Cooling Functions · Titanium Heat Exchanger · Extremely quiet operation – only 27-34db(A) at 10m (depending on model and power output mode) · Reduced startup current – no soft start required

Weight

Quantity
-
+

Inventory

隐藏域元素占位

  • Feature
  • Specification

  • EVl technology conquers all climates

    The EVl compressor allows the gas to be re-injected into the compressor in an optimal way, achieving higher temperatures in low ambient. The main advantages of this technology are:

     

    • lmprovement of performance and output water temperature.
    • lmprovement of the seasonal performance.
    • Higher utilization of the heating capacity of the system.

     

    The EVl Inverter heat pump can reach temperatures of over 60°C with no additional electrical support, even at the most extreme temperatures.
     

     

     

    Inverter technology

    Stable water temperature

    Precise control of the compressor speed ensures that the water temperature remains within a small fuctuation around the set temperature.

     

    Quick start-up

    Inverter system outputs power according to the energy demand, it starts quickly by adjusting motor rotary frequency, and reaches a comfortable state in a short time.

     

    Less frequesnt start/stop

    The ability to vary compressor speed means fewer start/stop cycles for the compressor, extending compressor life.

     

    All-season fun

    Unique EVl technology by means of the Flash Tank system allowing to offer the best performances even in the most unfavourable conditions from ambient -25oC to 43oC, making it fit
    for all-year-round swim.

    High efhciency

    Specially developed with the most cutting-edge technology and modern design to meet stringent requirements for effciency PAT EVl inverter heat pump is featured with top energy rating COP up to 15, the unit is currently most energy effcient and can greatly reduce energy bills for customers.

    Quiet operation

    Extremely quiet operation, compressor and fan work at low speed when maintaining the temperature, cut the noise level to around 38 dB(A) at midnight.

     

  • Model WE-07 WE-09 WE-12 WE-14 WE-17
    Condintion 1: (A26°C, RH70%/ W26℃/28°C) Heating capacity kW 1.63-7.25 1.98-9.25 2.72-12.2 3.41 -14.33 4.33-17.45
    Power input kW 0.14-1.17 0.15-1.27 0.18-1.97 0.22-2.33 0.30-2.87
    Current A 0.6-5.2 0.7-5.6 0.82-8.95 1.0-10.2 1.3-12.6
    COP   11.64-6.20 13.20-7.28 15.1-6.47 15.5-6.15 14.43-6.08
    Condintion 2: (A15°C, RH70% / W26°C/28℃) Heating capacity kW 1.50-5.87 1.84-7.71 2.51-10.35 3.28-12.25 4.01 -14.92
    Power input kW 0.18-1.10 0.23-1.36 0.27 -1.85 0.39-2.27 0.49-2.68
    COP   8.33 -5.34 8.00-5.67 9.30-6.10 8.41-5.40 8.18-5.57
    Condintion 3: (A7°C, RH70% / W26℃/28°C) Capacity kW 1.31-5.10 1.60-6.71 2.18-9.32 2.85-10.66 3.49-12.98
    Rated input kW 0.17-1.01 0.21-1.24 0.25-1.35 0.36-2.08 0.45-2.45
    COP   7.91-5.07 7.60-5.39 8.83-7.80 7.98-5.13 7.77-5.29
    Condintion 4:(A35℃,W28°C/26°C) Cooling capacity kW 1.70-3.65 1.80-4.60 2.45-7.10 3.20-7.90 3.90-9.80
    Power input kW 0.22-0.81 0.28-1.20 0.33-1.71 0.43 -1.80 0.51-2.42
    COP   7.73 -4.51 6.43 -3.83 7.42-4.47 7.44-4.39 7.65-4.05
    Power supply   V~/Ph/Hz 220-240V~/1ph/50Hz
    Water flow   M3/h 3-4 3-5 4-6 5-7 6-8
    Running temperature range     -25~43
    Advised pool size (lsothermal cover @ night)   m3 15~30 20~40 25~50 30~60 35~70
    R32 Refrigerant  

    kg

    0.8 0.8 0.94 1.3 1.5
    CO2 Equivalent   T 0.5 0.5 0.6 0.9 1.0
    Water side heat-exchanger     Titanium heat-exchanger, Titanium tube with PVC casing
    Sound pressure level @1m   dB(A) 44 47 47 48 50
    Controller     LCD, built-in Wifi module
    Unit/Packing dimension (LxDxH)   mm 865x400x665 / 985x403x820 990x425x670 / 1120x452x845

     

    Model WE-21 WE-23 WE-25 WE-29 WE-32
    Condintion 1: (A26°C,RH70% / W26°C/28°C) Heating capacity kW 4.80 -21.15 5.71-23.00 6.20-25.15 6.60-29.00 7.70-31.80
    Power input kW 0.33 - 3.31 0.38 -3.78 0.43-4.08 0.45 -4.73 0.54-5.33
    Current A 1.4 - 14.5 1.7-16.6 1.9-17.9 2.0-20.8 2.4-23.4
    COP   14.55 -6.39 15.03-6.08 14.42 -6.16 14.67-6.13 14.26 -5.97
    Condintion 2: (A15°C,RH70% / W26°C/28°C) Heating capacity kW 4.30 -17.00 15.33 - 18.55 5.92 -21.26 6.24-24.35 6.86-27.00
    Power input kW 0.50 -2.88 0.64 - 3.68 0.69-3.80 0.77 -4.38 0.91-4.95
    COP   8.60-5.90 8.33-5.04 8.58-5.59 8.10-5.56 7.54-5.45
    Condintion 3: (A7°C,RH70% / W26°C/28°C) Capacity kW 3.74 - 14.79 4.64 -16.14 5.15 -18.49 5.42-21.18 5.95 -23.45
    Rated input kW 0.46-2.64 0.59-3.38 0.63-3.48 0.71-4.01 0.83-4.54
    COP   8.17-5.60 7.91-4.78 8.15 - 5.31 7.69-5.28 7.16-5.17
    Condintion 4: (A35°C,W28°C/26°C) Cooling capacity kW 4.30 - 11.55 5.30- 13.10 5.80-14.00 6.20-16.20 7.30-17.50
    Power input kW 0.56-2.61 0.73 -3.34 0.80-3.38 0.82-3.75 0.99 - 4.16
    COP   7.68 -4.43 7.26- 3.92 7.25 -4.14 7.56-4.32 7.37 -4.21
    Power supply   V~/Ph/Hz 220-240/1/50
    Water flow   M3/h 7-9 8-10 8-11 9-12 12-15
    Running temperature range     -25°C~43°C
    Advised pool size (lsothermal cover @ night)   m3 40-80 60-100 65-110 70~130 80-150
    R32 Refrigerant  

    kg

    2.1 2.1 2.1 2.7 3
    CO2 Equivalent   T 1.4 1.4 1.4 1.8 2.0
    Water side heat-exchanger     Titanium heat-exchanger with PVC casing
    Sound pressure level @1m   dB(A) 51 53 54 57 60
    Controller     LCD, built-in Wifi module
    Unit/Packing dimension (LxDxH)   mm 1085x480x725/1180x500x880 1216x451x822/1351x515x957
    Net/Gross weight   kg 77 /95 77 /95 77 /95 90 /105 98 /113
    Loading quantity 40HQ     80 80 80 66 66